Set-DaikinAirCon
SYNOPSIS
SYNTAX
Set-DaikinAirCon [[-HostName] <Object>] [[-PowerOn] <Boolean>] [[-Temp] <Int32>] [[-Mode] <Object>]
[[-FanSpeed] <Object>] [[-FanDirection] <Object>] [-ProgressAction <ActionPreference>] [<CommonParameters>]
DESCRIPTION
Cmdlet allows to configure the aircon device to the desired setting.
EXAMPLES
EXAMPLE 1
Set-DaikinAirCon -HostName daikin.local.network -PowerOn:$true -Temp 19 -Mode AUTO -FanSpeed AUTO -FanDirection Stopped
This example configures the aircon device to the specified parameter values.
PARAMETERS
-HostName
Hostname or IP of the Daikin AirCon device.
Type: Object
Parameter Sets: (All)
Aliases:
Required: False
Position: 1
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-PowerOn
Set to $true or $false to specify if the master power should be on or off. This does not the affect the connectivity of the control surfice.
Type: Boolean
Parameter Sets: (All)
Aliases:
Required: False
Position: 2
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
-Temp
Specified the target temperature in celcius.
Type: Int32
Parameter Sets: (All)
Aliases:
Required: False
Position: 3
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-Mode
Specifies the operating mode of the aircon device. Allowed values are; AUTO : Switches between heat and cold depending on the current and target temperature. DRY : Sets the device lower the humidity of the air. COLD : Sets the device chill the air if needed. No heat will be provided. HEAT : Sets the device heat the air if needed. No chilling of air will be provided. FAN : Sets the device to only circulate air without affecting temperature or humidity.
Type: Object
Parameter Sets: (All)
Aliases:
Required: False
Position: 4
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-FanSpeed
Specifies the strenght of the fan. Allowed values are; AUTO : Sets the device to manage fan speed to keep the target climate. SILENT : Sets the fan speed to minimize noise. Level_1 -> Level_5 : Sets the fan speed to the target level.
Type: Object
Parameter Sets: (All)
Aliases:
Required: False
Position: 5
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-FanDirection
Specifies how the direction of airflow is controlled. Allowed values are Stopped, VerticalSwing, HorizontalSwing and BothSwing
Type: Object
Parameter Sets: (All)
Aliases:
Required: False
Position: 6
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-ProgressAction
{{ Fill ProgressAction Description }}
Type: ActionPreference
Parameter Sets: (All)
Aliases: proga
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
CommonParameters
This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
INPUTS
OUTPUTS
NOTES
RELATED LINKS
EDIT THIS DOC